Titan Accelerometer

Sensor Accelerometer 3 Komponen

Categories: Accelerometer

The Titan accelerometer features industry leading dynamic range and ultra-low self-noise performance that is comparable to that of some broadband seismometers. The Titan is the first accelerometer to incorporate digitally selectable full scale range and offset zeroing capabilities; features that are ideal for difficult to access or remote deployments, where site visits should be minimized.

COMPACT DESIGN

The triaxial sensor and electronics are housed in a rugged, compact aluminum enclosure featuring a single bolt anchoring slot, adjustable leveling screws and integrated bubble level.

ZEROING CAPABILITIES

The Titan is the first accelerometer to incorporate digitally selectable full scale range and offset zeroing capabilities; features that are ideal for difficult to access or remote deployments, where site visits should be minimized.

Product Detail Description

Topology: Triaxial, horizontal-vertical

Feedback: Force balance with capacitive displacement transducer

Centering: Electronic offset zeroing via user interface or control line

Full-scale Range: Electronically selectable range: ±4g, ±2g, ±1g, ±0.5g, and ±0.25g (peak)

Bandwidth: DC to 430 Hz (-3 dB point)

Dynamic Range: (Integrated RMS)
• 166 dB @ 1 Hz over 1 Hz bandwidth
• 155 dB, 3 to 30 Hz

Offset: Electronically zeroed to within ±0.005g

Non-linearity: < 0.015% total non-linearity

Hysteresis: < 0.005% of full scale

Cross-axis Sensitivity: < 0.5% total

Offset Temperature Coefficient:
• Horizontal sensor: 60 μg/°C, typical
• Vertical sensor: 320 μg/°C, typical
 

Commands: Gain range selection
• Auto-zero, or set to specific offset
• Self-test
• Calibration enable
• State of health request
• Firmware updates

Data Outputs:
• Sampled XYZ outputs (in volts and g)
• Instrument temperature
• Trimmer settings
• Instrument serial number
• Hardware assemblies and firmware revisions
 

Connectors: MIL-C-26482G Series 1, 14-pin, shell size 12

Acceleration Output: 40 Vpp differential

Output Impedance: 2 x 100 Ω

Calibration Input: Single voltage input, all channels enabled together

Control Input: Single control signal can be configured to initiate auto-zero, initiate self-test, or enable calibration

Status Output:
• Asserted: Unit OK, output signal valid
• Deasserted: Self-test in progress or failed, autozeroing in progress, calibration enabled, or starting up

Serial Port: 9600 Baud RS-232 compatible
 

Supply Voltage: 9 to 36 V DC isolated input

Power Consumption: 1.1 W typical quiescent

Protection:
• Reverse-voltage and over-/undervoltage protected
• Self-resetting over-current protection

Isolation: Supply power is isolated from signal ground

Grounding: Predrilled holes (4) for M4 x 5 grounding lug screw

Voltage Disconnect: Software configurable (low/high)
 

Housing: Aluminum, surface resistant to corrosion, scratches, and chips

Mounting: Single bolt keyhole mount

Leveling:
• Integrated bubble level
• Adjustable locking leveling screws

Size:
• Length: 140 mm
• Width: 85 mm
• Height: 58 mm
• Weight: 960 g

Shock:
• 100 g half sine, 5 ms without damage, 6 axes
• No mass lock required for transport

Operating Temperature: -20°C to +60°C

Storage Temperature: -40°C to +70°C

Humidity: 0 to 100%

Ingress Protection: Rated to IP68 at 2 m for 72 hours
 