Trilium 120 Posthole Seismometer

Trilium 120 Posthole Seismometer

Categories: Seismometer

Nanometrics’ industry-leading portfolio of Trillium seismometers includes a posthole variant that is revolutionizing the way seismologists deploy instruments and collect seismic data. The instrument is housed in a stainless steel enclosure incorporating a high-pressure, marine-grade connector making it suitable for uncased buried/posthole installations. An advanced leveling system allows the instrument to self-correct over a tilt range of ±5 degrees (±10 degrees optional).

The Trillium PH is ideal for local, regional and teleseismic studies having a response flat to velocity from 120 seconds to 150 Hz and self-noise below the NLNM at 100 seconds. Operators will appreciate the low power consumption, automatic mass centering and robust no-mass lock design inherent in all Trillium seismometers.

When using the Trillium 120 PH with our popular Centaur digitizer, you’ll have access to a digital leveling bubble through the Centaur GUI. The virtual leveling bubble makes for easy leveling down a dark hole, or once buried, gives you the ability to check levelness at any time.

Product Detail Description

Self-Noise: See plot below

Nominal Sensitivity: 1200 V-s/m (reference User Guide for precise value)

Precision: ±0.5% relative to User Guide specification

Bandwidth: -3 dB points at 120 s and 150 Hz

Clip Level: 16.6 mm/s up to 10 Hz and 0.12 g above 10 Hz

Dynamic Range: 168 dB @ 1 Hz

Operating Tilt Range: ±5º

Temperature: ±45°C without recentering

Magnetic Sensitivity: <0.03 (m/s²)/T (model T120-PH3-XC)

Connector: 20-pin marine

Velocity Output: 40 V peak-to-peak differential

  • Selectable XYZ or UVW mode

Mass Position Output: Three independent ±4 V outputs

Calibration Input: Single voltage input with one active-high control signal for all channels

  • Calibration in XYZ or UVW
  • Individual channels selectable via web interface

Control Lines: Auto-Level & Mass Center, Calibration Enable, XYZ/UVW mode

Serial Port:

  • RS-232 compatible serial IP (SLIP) with onboard HTTP web server to select sensor operating modes, to mass center, and to access state-of-health, virtual level bubble, firmware updates and metadata
  • Plug-and-Play automated workflow interface to select sensor operating modes, and to access state-of-health, virtual level bubble and metadata

Supply Voltage: 9 to 36 Volts DC isolated input

Power Consumption: 230 mW typical quiescent

Protection:

  • Reverse-voltage and over-voltage protected
  • Self-resetting over-current protection

Operating Temperature:

  • –20°C to 60°C (Standard Model)
  • –50°C to 60°C (Polar Certified Model)

Storage Temperature:

  • –40°C to +70°C (Standard Model)
  • –60°C to +70°C (Polar Certified Model)

Ingress Protection: Rated to IP68 and NEMA6P to 300 m for prolonged immersion. A dry hole is recommended for the best seismic performance.

Humidity: 0% to 100% (submersible)

Shock: 20 g half sine, 5 ms without damage, 6 axes. No mass lock required for transport.

trillium_ph_120.pdf

Related Product

centaur.png
Centaur Digitizer

Digitizer

bullet-gps1.png
Trimble Bullet GPS

Communication

cygnus.png
Cygnus 210

Communication

FY23-Apollo-Software-Product-v2.png
APOLLO

Software

athena.png
ATHENA

Software

Contact Us

Thanks!

I'll be in touch ASAP